Showing posts with label Biochemistry. Show all posts
Showing posts with label Biochemistry. Show all posts

Wednesday, November 23, 2016

Antibody purification

Buffers and Reagents:

Column: HiTrap NHS-activated HP 1 ml

Coupling buffer - 0.2 M NaHCO3 , 0.5 M NaCl, pH 8.3

Buffer A - 0.5 M Ethanolamine, 0.5 M NaCl, pH 8.3

Buffer B - 0.1 M Sodiumacetate, 0.5 M NaCl, pH 4.0

1 mM HCl

2 M glycine-HCl pH 2.0

0.1% PBS/NaN3

PBS

50 mM glycine-HCl pH 2.75

50 mM TAE pH 11.5

Buffer A - 0.5 M Ethanolamine, 0.5 M NaCl, pH 8.3

Buffer B - 0.1 M Sodiumacetate, 0.5 M NaCl, pH 4.0


Protocol:

Preparation of the peptide: Weigh 5 mg of the peptide and dissolve in 1 ml coupling buffer by vortexing.

Determine the protein concentration by measuring absorption at 280 nm using spectrophotometer.

Coupling to the column-

Fill 5 ml syringe with 1 mM HCl. Couple the column by placing the syringe on the yoke of the column.

Activation of the column-

Activate the column and wash away the isopropanol from the column by passing 6 ml of 1 mM HCl through the column. 

Coupling of the peptide-

Connect the column with two syringes, one on the upper side and other on the lower side. Fill the upper syringe with peptide solution and press it slowly on the column. The upper syringe will be empty and lower will be filled up half. Incubate the column for 1 hour at 4 oC. Then press the lower syringe slowly in order to move the solution to the upper syringe. Again incubate the set up at 4 oC for 1 hour. Move the peptide solution once every hour between two syringes for up to 4 hours. Incubate the whole set up at 4 oC overnight. 

Next day-

Remove the lower syringe and let the peptide solution drop out of the column. Preserve the flow through.

Washing of the column-

Wash the column twice using 1 ml coupling buffer. Preserve the flow through and mix it with the previous one. Mix 1 ml of the flow through with 1 ml of 2 M glycine-HCl pH 2.0 and measure the absorption at 280 nm. 

Determination of the coupling efficiency-

Volume of the coupled peptide solution:
A = A280, coupling solution X Vloaded volume of coupling solution

Volume of the not coupled peptide:
B = A280, post-coupling wash after acidification X VVolume post-column wash X 2(dilution when acidified)

Coupling yield, %:
(A-B)/A x 100 = Z
Z% of the peptide solution is coupled to the column. 

Denaturation of the column-

Denature the column by passing 2 ml of buffer A, 2 ml of buffer B and again 2 ml of buffer A. Repeat the sequence thrice and incubate the column at 25 oC for 30 minutes. Post 30 minutes, pass 2 ml of buffer B, 2 ml of buffer A and 2 ml of buffer B through the column and repeat the sequence thrice followed by incubation at 25 oC for 30 minutes.

Equilibration of the column-

Equilibrate the column by washing it with 10 ml of PBS once. 

Storage of the column-

Add 2 ml of 0.1% PBS/NaN3 to the column and store the column at 4 oC.

Antibody purification-

1. Defrost the bleed and take 10 ml out. Freeze back the rest of the bleed at -80 oC.
2. Centrifuge the serum at 40,000 rpm, for 1 hour at 4 oC using ultracentrifuge.
L1 = clear, thick layer
L2 = pink, thin layer
3. Remove the L2 layer carefully with pasteur pipette and place it on ice.
4. Wash the coupled column with 10 ml of PBS.
5. Absorb the serum in a 5 ml syringe and place it on the column. Arrange the second syringe at the other end of the column.
6. Move the serum within the syringes every 15 minutes for up to 3 hours at 4 oC.
7. Collect the sample from the flow through.
8. Wash the column using 10 ml of PBS.
9. Elute the antibody with 10 ml of 50 mM glycine-HCl pH 2.75 and place the eluate on ice.
10. Again wash the column using 10 ml of PBS.
11. Elute the antibody with 10 ml of 50 mM TAE pH 11.5 and place the eluate on ice.
12. Wash the column using 20 ml of PBS and store the column in PBS/NaN3 at 4 oC.
13. Concentrate the eluates to a volume of 4 ml using 30 kDa Amicon’s membranes. Thereafter, dialyse the eluates in PBS for 2 hours and then in PBS/50% Glycerol overnight at 4 oC. 

Estimation of protein using Bicinchoninic acid (BCA)

This method was developed by Smith et al in 1985 and thereafter, Pierce Chemical Company exploited it by developing a kit. In this method, there is reduction of cupric ions to cuprous ions by the protein under alkaline condition. The cuprous ions are detected by using bicinchoninic acid (BCA). The macromoecular structure of the protein, the number of peptide bonds and the presence of four amino acids (cysteine, cystine, tyrosine, tryptophan) are responsible for color development in protein samples. Accordingly, protein concentrations generally are determined and reported with reference to standards of a common protein such as bovine serum albumin (BSA).

Reagents: 

BCA Protein Assay kit is available from Pierce, Rockford, Il 61105, USA. The reagent kit has the following reagents:

Reagent A (sodium carbonate, sodium bicarbonate, bicinchoninic acid and sodium tartarate in 0.1 M sodium hydroxide)

Reagent B (4% cupric sulfate)

Albumin Standard Ampules, 2 mg/ml: Prepare bovine serum albumin (BSA) at 2.0 mg/ ml in 0.9% saline and 0.05% sodium azide

Just before use, prepare working BCA reagent by mixing one part of Reagent B with 50 parts of Reagent A. 

Protocol:

Spectrophotometer-

Prepare a series of dilutions of known concentration from the protein and assay alongside the protein sample of unknown concentration.

1. Prepare standard series by taking aliquots of the BSA protein in different tubes so that amount of the protein in different tubes varies from 5 to 50 μg protein.
2. Take aliquot of protein and water to make the volume 1.0 ml.
3. Prepare the blank by taking 1.0 ml of water.  
4. Add 2 ml of working BCA reagent in each tube and shake well.
5. Incubate all the tubes at 37oC for 30 minutes.
6. Measure the absorbance at 562 nm in a spectrophotometer.
7. Taking into account the readings with standard proteins, plot a calibration curve taking absorbance on the vertical axis and amount of the protein on the horizontal axis.
8. From this plot, using absorbance value with the unknown protein, determine the amount of the protein in the unknown sample.

Plate reader-

1. Prepare standard series by taking aliquots of the BSA protein in different wells so that amount of the protein varies from 0-25 μg protein. 
Standard (Volume in µl)
H2O
25
20
15
10
0
BSA (1 µg/µl)
0
5
10
15
25
2. Take aliquot of protein and water to make the volume 25 µl.
3. Add 200 µl of working BCA reagent in each well and place the plate on shaker at 37 oC for 30 minutes in dark.
4. Measure the absorbance at 562 nm using plate reader.
5. Taking into account the readings with standard proteins, plot a calibration curve taking absorbance on the vertical axis and amount of the protein on the horizontal axis.
6. From this plot, using absorbance value with the unknown protein, determine the amount of the protein in the unknown sample.

Although the method has several advantages viz. compatibility with ionic and non-ionic detergents, stable working reagent, less protein to protein variation, broad linear working ranges and good sensitivity; reducing agents and copper chelators do interfere with this assay. This problem can be ruled out by removing the interfering substances prior to BCA analysis by precipitating the protein sample with TCA or acetone and re-dissolving the protein pellet in NaOH or water. Some people prefer to bind proteins to positively charged nylon at alkaline pH and washing out the non-bound interfering agents.

Tuesday, November 22, 2016

Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE)

Perform SDS-PAGE for separation of proteins according to a modified protocol (Laemmli, 1970; Matsudaira and Burgess, 1978). Sodium dodecyl sulfate, an anionic detergent, is used to completely suppress the native charge on the proteins. It gives them a large negative coat of detergent molecules. The SDS also interacts with the hydrophobic core of proteins, it causes a rapid and irreversible unfolding that linearizes the polypeptide chains which all now have a roughly equivalent charge/mass ratio. Therefore, in SDS-PAGE, the separation of proteins is on the basis of molecular weight (size) of the proteins.

Buffers and Reagents:

Lower Gel Stock Solution (1.0 M Tris-HCl, pH 8.8; 0.25% SDS)

60.6 g Tris-HCl
1.25 g SDS
Dissolve in H2O, adjust the pH 8.8 with HCl and make the volume 500 ml with H2O.

Upper Gel Stock Solution (0.5 M Tris-HCl, pH 6.8; 0.25% SDS)

15.2 g Tris-HCl
0.63 g SDS
Dissolve in H2O, adjust the pH 6.8 with HCl and make the volume 250 ml with H2O.

1X SDS Running Buffer (0.19 M Glycine; 25 mM Tris-HCl, pH 8.3; 0.1 % SDS)

7.2 g Glycine
1.5 g Tris-HCl
0.5 g SDS
Dissolve in H2O, adjust the pH 8.3 and make the volume 500 ml with H2O.

5X SDS Sample Buffer (0.25 M Tris-HCl, pH 6.8; 50% Glycerol; 5% SDS and 0.1% Bromophenol blue)

1.2 g Tris-HCl
20 ml Glycerol
10 ml of 20% SDS
0.04 g Bromophenol blue
Dissolve in H2O, adjust the pH 6.8 and make the volume 40 ml with H2O.

** CAUTION ** SDS powder is hazardous. Prepare solution in a ventilated fume hood. 

Protocol:

For casting gels, a system with vertically oriented glass plates with 1 mm spacer in between can be used. Prepare separating gel (small pore size gel) and stacking gel (large pore size gel) as first described by Ornstein, 1964.

Composition of separating and stacking gel:

Components
Separating gel
Separating gel
Stacking gel (4%) (ml)

10% (ml)
17% (ml)

40% Acrylamide/ Bis acrylamide (37.5:1)
15
25.6
5.4
Tris HCl (1.0 M, pH 8.8)
22
22
-
Tris HCl (0.25 M, pH 6.8)
-
-
27
10% SDS
0.6
0.6
0.54
TEMED
0.12
0.12
0.108
10% APS
0.065
0.065
0.065
H2O
22
11.5
20.9

First pour the separating gel between glass plates and apply a layer of isopropanol on it. After polymerization of the separating gel, remove the layer of isopropanol and wash the polymerized gel with H2O. Then pour the stacking gel on the top of the polymerized separating gel and insert the comb. When the gel solution gets solidified, place the gel in the electrophoresis chamber filled with the 1X SDS running buffer and remove the comb. Mix the protein sample to be electrophoresed with 5X SDS sample buffer and denature it completely by heating at 95oC for 5 minutes. Then load the denatured protein samples along with the molecular weight marker proteins and perform the electrophoresis at 150 volts. Stop the current when the bromophenol blue tracking dye reaches at the end.

Molecular weight protein markers that can be used:

Protein name
Molecular weight (kDa)
β-Galactosidase
116.0
Bovine serum albumin
66.2
Lactate-dehydrogenase
45.0
Restriction endonuclease Bsp981
35.0
Lactoglobulin
18.0
Lysozyme
14.4